Home › Physics & Chemistry › Vapor Pressure Deficit Calculator

Vapor Pressure Deficit Calculator

This vapor pressure deficit calculator shows how strongly the air pulls moisture from plant leaves. Growers use VPD to balance temperature and humidity in greenhouses and grow rooms.

How VPD is calculated

Saturation pressure (kPa) = 0.61078 × e17.27T ÷ (T + 237.3)
VPD = saturation pressure at leaf temperature − saturation pressure at air temperature × RH

This uses the Tetens formula. With the leaf at air temperature, VPD is simply the saturation pressure × (1 − RH).

Common VPD ranges

VPD (kPa)Often used for
0.4–0.8Seedlings, cuttings, propagation
0.8–1.2Vegetative growth
1.2–1.6Flowering and fruiting
Below 0.4 or above 1.6Usually avoided

These are common grower guidelines; ideal values differ between crops.

Tips

  • Measure leaf temperature with an infrared thermometer; leaves under lights may be warmer, leaves in moving air cooler.
  • For dew and condensation risk, use the dew point calculator; for heat stress in people, the heat index calculator.

Frequently asked questions

What is a good VPD?

Roughly 0.8–1.2 kPa for most plants in active growth, a little higher when flowering.

How do I lower VPD?

Raise humidity or lower temperature.

Why does leaf temperature matter?

Transpiration depends on the vapour pressure at the leaf surface, not the air.