How VPD is calculated
Saturation pressure (kPa) = 0.61078 × e17.27T ÷ (T + 237.3)
VPD = saturation pressure at leaf temperature − saturation pressure at air temperature × RH
This uses the Tetens formula. With the leaf at air temperature, VPD is simply the saturation pressure × (1 − RH).
Common VPD ranges
| VPD (kPa) | Often used for |
|---|---|
| 0.4–0.8 | Seedlings, cuttings, propagation |
| 0.8–1.2 | Vegetative growth |
| 1.2–1.6 | Flowering and fruiting |
| Below 0.4 or above 1.6 | Usually avoided |
These are common grower guidelines; ideal values differ between crops.
Tips
- Measure leaf temperature with an infrared thermometer; leaves under lights may be warmer, leaves in moving air cooler.
- For dew and condensation risk, use the dew point calculator; for heat stress in people, the heat index calculator.
Frequently asked questions
What is a good VPD?
Roughly 0.8–1.2 kPa for most plants in active growth, a little higher when flowering.
How do I lower VPD?
Raise humidity or lower temperature.
Why does leaf temperature matter?
Transpiration depends on the vapour pressure at the leaf surface, not the air.
Written and checked by Vijay. Last updated .