ENERGY STAR room AC sizing chart
| Area to be cooled (sq ft) | Capacity needed (BTU per hour) |
|---|---|
| 100 up to 150 | 5,000 |
| 150 up to 250 | 6,000 |
| 250 up to 300 | 7,000 |
| 300 up to 350 | 8,000 |
| 350 up to 400 | 9,000 |
| 400 up to 450 | 10,000 |
| 450 up to 550 | 12,000 |
| 550 up to 700 | 14,000 |
| 700 up to 1,000 | 18,000 |
| 1,000 up to 1,200 | 21,000 |
| 1,200 up to 1,400 | 23,000 |
| 1,400 up to 1,500 | 24,000 |
| 1,500 up to 2,000 | 30,000 |
| 2,000 up to 2,500 | 34,000 |
Capacities assume an 8-foot ceiling. Adjustments: heavily shaded room −10%; very sunny room +10%; add 600 BTU for each person above two; add 4,000 BTU for a kitchen.
Example
A 12 × 20 ft room is 240 sq ft, which falls in the 150–250 band: 6,000 BTU. If it's very sunny (+10% = 6,600) and four people use it (+1,200), you'd want about 7,800 BTU, so an 8,000 BTU unit.
Tips
- Bigger isn't better: an oversized unit cools the air before removing humidity, so the room feels clammy.
- For ceilings above 8 feet, consider the next size up.
- Need the floor area of an L-shaped room? Add up the rectangles with the square footage calculator.
Frequently asked questions
What size AC do I need for a 300 sq ft room?
About 7,000 BTU per hour on the ENERGY STAR chart, before adjustments for sun, people or a kitchen.
How many BTUs is a ton?
One ton of cooling is 12,000 BTU per hour.
Is this for central air?
It's for room (window or portable) units. Central systems should be sized with a Manual J load calculation by an HVAC contractor.
Sources: ENERGY STAR (US EPA), Room air conditioners: properly sized room air conditioners.
Written and checked by Vijay. Last updated .